Konica Minolta
Range 7 Range 7

KONICA MINOLTA RANGE7

Specifications

Specifications of Konica Minolta Non-Contact 3D Digitizer RANGE7

Measuring method Triangulation light block method
Light source Semiconductor laser; Wavelength: 660nm
Laser class Class 2 (IEC60825-1 Amendment 2)
Number of pixels taken 1.31 megapixels (1280×1024)
Measurement distance 450mm to 800mm
Receiving lens TELE; WIDE
Measurement range (Units: mm)   X × Y Z
TELE; Distance: 450mm 79×99 54
TELE; Distance: 800mm 141×176 97
WIDE; Distance: 450mm 150×188 109
WIDE; Distance: 800mm 267×334 194
XY direction measurement interval (Units: mm) TELE; Distance: 450mm 0.08
TELE; Distance: 800mm 0.14
WIDE; Distance: 450mm 0.16
WIDE; Distance: 800mm 0.28
Accuracy (Distance between balls)*1 ±40µm
Precision (Z, s)*2 4µm
Autofocus Yes
Autoexposure Yes
Scan time Approx. 2 sec. (1 scan)
Preview function Yes (Approx. 0.4 sec./scan)
Ambient lighting condition 500lx or less
File format*3 Input/output: Konica Minolta proprietary formats .rgv, .rvm; Output only: .stl
Output interface USB 2.0 High Speed
Power Included AC Adapter
Input voltage: AC 100 to 240V (50/60Hz)
Rating: 1.4A (at AC 100V input)
Dimensions 295 (W) × 190 (H) × 200 (D) mm (Not including grips and lens)
Weight Approx. 6.7kg
Operating temperature/humidity range 10 to 40°C; Relative humidity 65% or less with no condensation
Storage temperature range -10 to 40°C; Relative humidity 85% (at 35°C) or less with no condensation
  1. When measuring distance between balls for a ball bar as defined in VDI/VDE 2634-2 under Konica Minolta measurement conditions.
    Konica Minolta measurement conditions: Temperature: 20±1°C; Lens: TELE; Measurement distance: 450mm; Warmup: 20 min.; Software used: Konica Minolta processing software; After calibration of instrument; Measurement subject: Konica Minolta standard (2 balls); Arrangement of measurement subject: Konica Minolta standard arrangement (10 locations inside measurement space); Uncertainty of standard not included
  2. Measurement conditions: Temperature: 20±1°C; Lens: TELE; Measurement distance: 450mm; Warmup: 20 min.; Measurement subject: Konica Minolta standard planar chart; Software used: Konica Minolta processing software; 1σ value
  3. Using Konica Minolta processing software

Specifications of Konica Minolta 3D Data Processing Software RANGE VIEWER

Main specifications
Readable formats Konica Minolta proprietary formats .rgv (Single-scan data cloud), .rvm (multiple data)
Data output ASCII point group; Binary point group (including normal vectors)
Konica Minolta proprietary formats .rgv, .rvm
Measurement functions Monitor image; Preview; AF/AE; Measurement
Control of rotary stage (Konica Minolta optional accessory)
Editing functions Data alignment; Data merging; Point group deletion
Drawing Point group shading

Operating environment
OS Windows Vista 64-bit (x64)
CPU Core2Duo, Xeon, or better
RAM 4GB or more
Display Graphics display capability of 1280×1024 or more
Graphics board OpenGL compatible board (verified-compatible board recommended)
Interface USB 2.0 port
  • Specifications and appearance shown herein subject to change without notice.
  • Product names used herein are trademarks or registered trademarks of their respective companies.